HST JBDS-300Y/500Y Digital Display Low-temperature Automatic Charpy Impact Testing Machine(-60°c/80°c)

HST JBDS-300Y/500Y Digital Display Low-temperature Automatic Charpy Impact Testing Machine(-60°c/80°c)
HST JBDS-300Y/500Y Digital Display Low-temperature Automatic Charpy Impact Testing Machine(-60°c/80°c)
HST JBDS-300Y/500Y Digital Display Low-temperature Automatic Charpy Impact Testing Machine(-60°c/80°c)

Introduction:
JBDS impact testing machine used to determine the metal material under dynamic load resistance to impact performance, in order to determine the material under dynamic load properties. The use of pendulum impact before the potential energy and the impact of the remaining potential energy difference in the dial displayed on the way to get the sample absorbed power. 

Standards

ASTM A370, BS EN ISO 148-1; EN10045, ASTM E23, GB/T3808-2002 ,GB/T229-2007. 


Advantages

The low temperature part adopts the cascade type compressor refrigeration technology, using the principle of thermal balance and circulation stirring mode, reach to the specimen automatic uniform cooling, constant temperature and temperature regulation. 

Specifications

MODEL

HST JBDS-300Y-60      HST JBDS-300Y-80

 

 

HST JBDS-500Y-60      HST JBDS-500Y-80

 

Impact energy (J)

150,300

250,500

Value of every grid (J)

0~300(2J), 0~150(1J)

0~500(5J), 0~250(2.5J)

Moment of pendulum(N·m)

0~300J(160.7695N·m), 0~150J(80.3848N·m)

0~500J(267.9492N.m), 0~250J(133.9746)

Impact velocity (m/s)

5.2

5.24

5.4

Distance between pendulum center and sample center (mm)

750

800

Raised angle

150º

Standard span (mm)

40+0.2

Round angle of jaws (mm)

R1-1.5((1mm is special order)

)

Round angle of striking edge (mm)

R2-2.5 or R8±0.05(8mm is special order)

 

Specimen holder support surface angle

 

11°

 

The impact of the blade angle

 

30°

 

The impact blade thickness (mm)

 

16

 

Size of specimen (mm)

55x10x10 , 55x10x7.5 , 55x10x5

Cooling way

Compressor

Compressor refrigeration

 

网易有道词典

---------------------------

Encountered an improper argument.

---------------------------

确定

---------------------------

 

Capacity of sample box

20

Range of low temperature

-60°c/80°c

Speed of sending specimen

≤2S

Power supply

3phs, 380V/220V±10%, 50Hz or specified

Dimensions (mm)

2124 x 600 x 1340

 

2144 x 736 x 1390

Gross weight(KG)

550

750

LEAVE A MESSAGE

You can also contact me via email. My email address is admin@hssdtest.com

Quickly Quotation:

+86-15910081986