Horizontal Flammability Tester and Vertical Burning Tester
Standards:
Request A Quote Files DownloadEquipment description:
This Horizontal and vertical flammability tester is applicable to solid materials and the apparent density measured according to GB6343 not less than 250kg/m2 of foam when placed in the horizontal and vertical with a small flame ignition source ignited combustion after the test. The machine has the use of safe, reliable, easy to operate, and so on.Meet UL 94 and EN 60695-2-11, IEC 60950
Specification:
|
Model |
HST- UL94 |
|
Control mode |
Keystroke control |
|
Outer box dimensions |
110*650*125(cm) |
|
Box volume |
≥0.5m³,With glass observation door |
|
Flame time |
0-99 minutes and 99 seconds can be set, accuracy ±0.1 second |
|
Residual flame time |
0-99 minutes and 99 seconds can be set, accuracy ±0.1 second |
|
The rest of the burining time |
0-99 minutes and 99 seconds can be set, accuracy ±0.1 second |
|
Test gas |
More than 98% methane/37MJ/m³ natural gas (coal gas is also available) |
|
Burner size parameters |
Adopt imported lamp, the inner diameter of spray can is 9.5±0.3mm, and the effective length of spray tube is 100±10mm |
|
Flame height |
It can be adjusted from 20mm to 175mm as required by standard |
|
Flowmeter |
105ml/min |
|
Gas leak detection |
Gas alarm device (optional) |
|
Power |
AC220V, 50Hz |