Widely used in universities, colleges, and enterprises in the fields of biology, chemical engineering, chemistry, pharmaceuticals, life sciences, and physical property testing.
Standards:
Request A Quote Files DownloadProduct Introduction
Widely used in universities, colleges, and enterprises in the fields of biology, chemical engineering, chemistry, pharmaceuticals, life sciences, and physical property testing. It provides users with a controlled, uniform, and constant temperature source for conducting constant temperature experiments or tests on experimental samples or manufactured products. It can also serve as a direct heating or cooling, or auxiliary heating or cooling heat source or cold source.
Product Features
● Latest independently developed temperature control technology, equipped with a high-standard PT100 and all imported electronic components.
● The software system can correct errors between the displayed temperature and the actual temperature, ensuring accurate temperature readings.
● Standard large-screen LCD display, providing a comprehensive view of multiple data points, with a temperature display resolution of up to 0.01℃.
● Over-temperature protection and over-temperature alarm; the over-temperature alarm temperature can be set, and the load can be automatically cut off when the temperature exceeds the limit.
● Timer function; the total operating time of the equipment can be set, and the load will be automatically cut off after the set time.
● Concealed cooling coil design ensures more usable space within the tank.
● Intelligent software ensures strong temperature stability. PID control automatically adjusts parameters to the optimal level for different media, and users can also manually readjust parameters.
● Software digital locking controls all system settings to prevent unauthorized operation and ensure accurate experimental data.
● High-efficiency, fully enclosed compressor cooling provides rapid cooling and multiple protections against overheating and overcurrent.
● Standard internal and external circulation function. The external circulation inlet and outlet pipes have an outer diameter of 10mm, meeting various user needs in different scenarios.
● Non-standard customization is supported.
Optional Accessories:
● Liquid Level Protection System – Forces load shutdown when the liquid level exceeds the limit, protecting users' experiments.
● RS485 Communication Interface – Connects to a computer or other host computer for device control and data viewing via software.
● Multi-Point Correction Function – Simultaneously corrects multiple temperature points to avoid temperature differences caused by sensor linearity errors.
● External PT100 – Enables precise temperature control for external circulation.
● Support – Allows different containers to be placed in the tank without being submerged in the constant-temperature liquid.
Technical Specifications:
|
Model |
Temperature Range(℃) |
Slot Depth(mm) |
Volume(L) |
Slot Opening(mm) |
Pump flow rate (L/min) |
Fluctuation(℃) |
Resolution (℃) |
Power(kw) |
External Dimensions (mm) |
|
SC-6 |
RT-100 |
150 |
6 |
180*160 |
6 |
0.05 |
0.01 |
1.0 |
300*380*440 |
|
SC-6A |
RT-200 |
150 |
6 |
180*160 |
Internal circulation |
0.1 |
0.01 |
1.2 |
340*380*440 |
|
SC-6B |
RT-300 |
150 |
6 |
180*160 |
Internal circulation |
0.1 |
0.01 |
1.5 |
550*380*475 |
|
SC-10 |
RT-100 |
200 |
10 |
180*160 |
6 |
0.05 |
0.01 |
1.4 |
300*380*490 |
|
SC-10A |
RT-200 |
200 |
10 |
180*160 |
Internal circulation |
0.1 |
0.01 |
1.5 |
340*380*490 |
|
SC-10B |
RT-300 |
200 |
10 |
180*160 |
Internal circulation |
0.1 |
0.01 |
1.7 |
550*380*475 |
|
SC-15 |
RT-100 |
200 |
15 |
250*160 |
6 |
0.05 |
0.01 |
1.8 |
340*380*490 |
|
SC-15A |
RT-200 |
200 |
15 |
250*160 |
Internal circulation |
0.1 |
0.01 |
2.0 |
340*380*490 |
|
SC-15B |
RT-300 |
200 |
15 |
250*160 |
Internal circulation |
0.1 |
0.01 |
2.2 |
550*380*475 |
|
SC-20 |
RT-100 |
150 |
20 |
330*280 |
6 |
0.05 |
0.01 |
1.9 |
480*520*550 |
|
SC-20A |
RT-200 |
150 |
20 |
330*280 |
Internal circulation |
0.1 |
0.01 |
2.1 |
480*520*550 |
|
SC-25 |
RT-100 |
300 |
25 |
250*160 |
6 |
0.05 |
0.01 |
2.0 |
340*380*620 |
|
SC-25A |
RT-200 |
300 |
25 |
250*160 |
Internal circulation |
0.1 |
0.01 |
2.2 |
340*380*620 |
|
SC-30 |
RT-100 |
230 |
30 |
330*280 |
13 |
0.05 |
0.01 |
2.1 |
480*520*550 |
|
SC-30A |
RT-200 |
230 |
30 |
330*280 |
Internal circulation |
0.1 |
0.01 |
2.3 |
480*520*550 |
|
SC-40 |
RT-100 |
200 |
40 |
400*380 |
13 |
0.05 |
0.01 |
2.5 |
550*630*520 |
|
SC-40A |
RT-200 |
200 |
40 |
400*380 |
Internal circulation |
0.1 |
0.01 |
2.7 |
550*630*520 |
|
SC-50 |
RT-100 |
300 |
50 |
350*320 |
13 |
0.05 |
0.01 |
3.0 |
480*610*620 |
|
SC-50A |
RT-200 |
300 |
50 |
350*320 |
Internal circulation |
0.1 |
0.01 |
3.2 |
480*610*620 |
|
SC-70 |
RT-100 |
300 |
70 |
600*300 |
13 |
0.05 |
0.01 |
3.4 |
420*845*640 |
|
SC-70A |
RT-200 |
300 |
70 |
600*300 |
Internal circulation |
0.1 |
0.01 |
3.5 |
420*845*640 |
|
SC-90 |
RT-100 |
300 |
90 |
800*300 |
13 |
0.05 |
0.01 |
4.5 |
430*1050*650 |
|
SC-90A |
RT-200 |
300 |
90 |
800*300 |
Internal circulation |
0.1 |
0.01 |
4.8 |
430*1050*650 |