HST-HB3000T-AZF-5 Five-station fully automatic Brinell hardness tester
Standards:
Request A Quote Files DownloadHST-HB3000T-AZF-5 Five-station fully automatic Brinell Hardness Tester
Product introduction:
1) The force value ranges from 62.5-3000kGF;12 kinds of Brinell ruler, which can be customized by users;
2) The Z-axis rises and falls automatically. After placing the sample, it rises automatically and begins to press marks.Electric loading closed-loop control, automatic loading;
3) Each gear force is automatically compensated, and the precision of the force value (3000Kg) is increased by one order of magnitude to 1/ 1000;
4) Automatic turret, indenter position and measurement position automatic conversion;
5) The host comes with three indenters ( 10, 5, 2.5mm), double objective lens (double magnification 20X/40X), no need to replace the indenter and measuring objective lens for large and small Brinell indentations;
6) When measuring indentation, it is fully automatic focusing without manual adjustment.
7) According to the standard block with different force value, the hardness value is automatically corrected.
8) Large sample space, large sample can be placed; On - the - go, no need to install the weight, no need to install debugging; Touch screen interface, easy to operate, any language version;
9) More sample and test information can be set and saved; Setting parameters of password protection;
10) The products are designed and produced by ourselves, with independent intellectual property rights and software Copyrights, which can be customized and upgraded for a long time
Technical Parameters:
|
Model |
HST-HB3000T-AZF-5 |
|
Brinell hardness scale |
HBW2.5/62.5 、HBW2.5/187.5 、HBW5/125 、HBW5/62.5 、 HBW5/250、HBW5/750、 HBW10/100 、HBW10/1500 、HBW10/3000 、HBW10/250 、HBW10/500、HBW10/1000 |
|
Test force ( Kgf) |
62 .5 kgf(612 .9 N) 、 100kgf(980 .7N) 、 125 kgf( 1226 N ) 、 187 .5kgf( 1839N )、 250kgf(2452N) 、500kgf(4903N) 、750kgf(7355N ) 、 1000kgf(8907N) 、 1500kgf( 14710 N ) 、3000kgf(29420 N) |
|
Carried standard |
JJG150 、 GB/ T 23 1 .2 |
|
Accuracy of test force |
62 .5 ~ 250kGF ≤ 1% 500 ~ 3000kGF ≤ 0. 5% |
|
Measuring device resolution |
0. 1 um |
|
Hardness resolution |
0 1 HBW |
|
Load holding time |
0 ~ 99 s |
|
Conversion scale |
HV,HK , HRA , HRBW , HRC , HRD , HREW , HRFW , HRGW , HRKW , HR15 N , HRFW , HRGW,HRKW , HR15 N , HR30N,HR45 N , HR15T , HR30T,HR45T |
|
Maximum allowable specimen height |
300 mm |
|
Size |
700*350*1050mm |
|
Weight |
180kg |
|
Package size |
850*580*1220mm |
|
Gross weight |
249kg |